STrategically Acquired Gradient Echo (STAGE) imaging, part III: Technical advances and clinical applications of a rapid multi-contrast multi-parametric brain imaging method Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): E. Mark Haacke, Yongsheng Chen, David Utriainen, Bo Wu, Yu Wang, Shuang Xia, Naying He, Chunyan Zhang, Xiao Wang, M. Marcella Lagana, Yu Luo, Ali Fatemi, Saifeng Liu, Sara Gharabaghi, Dongmei Wu, Sean K. Sethi, Feng Huang, Taotao Sun, Feifei Qu, Brijesh K. Yadav Abstract
One major thrust in radiology today is image standardization with a focus on rapidly acquired quantitative multi-contrast information. This is critical for multi-center trials, for the collection of big data and for the use of artificial intelligence in evaluating the data. Strategically acquired gradient echo (STAGE) imaging is one such method that can provide 8 qualitative and 7 quantitative pieces of information in 5 min or less at 3 T. STAGE provides qualitative images in the form of proton density weighted images, T1 weighted images, T2* weighted images and simulated double inversion recovery (DIR) images. STAGE also provides quantitative data in the form of proton spin density, T1, T2* and susceptibility maps as well as segmentation of white matter, gray matter and cerebrospinal fluid. STAGE uses vendors' product gradient echo sequences. It can be applied from 0.35 T to 7 T across all manufacturers producing similar results in contrast and quantification of the data. In this paper, we discuss the strengths and weaknesses of STAGE, demonstrate its contrast-to-noise (CNR) behavior relative to a large clinical data set and introduce a few new image contrasts derived from STAGE, including DIR images and a new concept referred to as true susceptibility weighted imaging (tSWI) linked to fluid attenuated inversion recovery (FLAIR) or tSWI-FLAIR for the evaluation of multiple sclerosis lesions. The robustness of STAGE T1 mapping was tested using the NIST/NIH phantom, while the reproducibility was tested by scanning a given individual ten times in one session and the same subject scanned once a week over a 12-week period. Assessment of the CNR for the enhanced T1W image (T1WE) showed a significantly better contrast between gray matter and white matter than conventional T1W images in both patients with Parkinson's disease and healthy controls. We also present some clinical cases using STAGE imaging in patients with stroke, metastasis, multiple sclerosis and a fetus with ventriculomegaly. Overall, STAGE is a comprehensive protocol that provides the clinician with numerous qualitative and quantitative images.
|
An evaluation of the reproducibility of 1H-MRS GABA and GSH levels acquired in healthy volunteers with J-difference editing sequences at varying echo times Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): James J. Prisciandaro, Mark Mikkelsen, Muhammad G. Saleh, Richard A.E. Edden Abstract
Recent advances in J-difference-edited proton magnetic resonance spectroscopy (1H MRS) data acquisition and processing have led to the development of Hadamard Encoding and Reconstruction of MEGA-Edited Spectroscopy (HERMES) techniques, which enable the simultaneous measurement of ɣ-aminobutyric acid (GABA), the primary inhibitory amino acid neurotransmitter in the central nervous system, and of glutathione (GSH), the most abundant antioxidant in living tissue, at the commonly available magnetic field strength of 3 T. However, the reproducibility of brain levels of GABA and GSH measured across multiple scans in human subjects using HERMES remains to be established. In the present study, twelve healthy volunteers completed two consecutive HERMES scans of the dorsal anterior cingulate cortex (dACC) to assess the test-retest reproducibility of the technique for GABA and GSH measurements at TE = 80 ms. Eleven of the twelve participants additionally completed two consecutive MEGA-PRESS scans at TE = 120 ms, with editing pulses configured for GSH acquisition, to compare the reliability of GSH in the same voxel measured using the standard MEGA-PRESS at TE = 120 ms. The primary findings of study were that, 1) the coefficient of variation (CV) of measuring GABA with HERMES was 16.7%, which is in agreement with the reliability we previously reported for measuring GABA using MEGA-PRESS; and 2) the reliability of measuring GSH with MEGA-PRESS at TE = 120 ms was more than twice as high as that for measuring the antioxidant with HERMES at TE = 80 ms (CV = 7.3% vs. 19.0% respectively). These findings suggest that HERMES and MEGA-PRESS offer similar reliabilities for measuring GABA, while MEGA-PRESS at TE = 120 ms is more reliable for measuring GSH relative to HERMES at TE = 80 ms.
|
In-situ observation for natural gas hydrate in porous medium: Water performance and formation characteristic Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Lunxiang Zhang, Mingrui Sun, Lingjie Sun, Tao Yu, Yongchen Song, Jiafei Zhao, Lei Yang, Hongsheng Dong Abstract
Extensive efforts have been made regarding gas hydrate sample reconstruction in the laboratory for a better understanding and development of natural gas resources. Magnetic resonance imaging (MRI) is a useful method for directly observing the reconstruction of methane hydrate, yet relevant studies remain limited. In this study, a 9.4-T 400-MHz MRI instrument was employed to investigate CH4 hydrate formation in porous media involving various initial water saturation levels and sand diameters. Pressure histories and MRI signal variations were monitored to discuss the process of CH4 hydrate growth, and the three main formation stages of induction, rapid growth, and slow formation were determined. Furthermore, the liquid water performance in MRI micro-images was analyzed to predict the characteristics of CH4 hydrate formation. The results indicated that CH4 hydrate formed in a spatially and temporally random manner and that pore plugging occurred owing to the residual water encased in grown hydrate. Additionally, phase saturations, water conversion percentages, and formation rates were defined to evaluate the effect of sand diameter and initial water saturation on CH4 hydrate formation. With the reduction in the diameter of quartz glass beads from 400 μm to 100 μm, the average hydrate formation rate increased from 0.0010 min−1 to 0.0034 min−1, respectively. When the initial water saturation decreased to the optimized value (0.22 in this study), the water conversion percentage and hydrate saturation increased.
|
Non-contrast enhanced diagnosis of acute myocarditis based on the 17-segment heart model using 2D-feature tracking magnetic resonance imaging Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Mona Salehi Ravesh, Matthias Eden, Patrick Langguth, Tim-Christian Piesch, Johanna Karolin Lehmann, Annett Lebenatus, David Hauttemann, Joachim Graessner, Norbert Frey, Olav Jansen, Marcus Both AbstractPurposeThe aim of this study was to investigate the diagnostic value of myocardial deformation analysis based on the 17-segment heart model using non-contrast enhanced (CE) 2D tissue feature tracking (2D-FT) technique.Material and methodsSeventy patients with suspected myocarditis underwent a cardiovascular magnetic resonance (CMR) examination at 1.5 Tesla. A contrast-agent-free part of this CMR protocol was additionally performed in forty healthy volunteers (HV). Besides standard CMR data sets, 2D-FT derived segmental and global longitudinal, radial, and circumferential deformation parameters were analyzed. The 2D-FT results were compared to the combined findings from CMR imaging and endomyocardial biopsy (EMB).ResultsPatients were assigned to three groups depending on their ejection fraction (EF) (<40%, 40–55%, ≥55%). Compared to HV, impaired EF (<55%) was significantly correlated to reduced segmental and global strain and strain rate values. The circumferential deformation analysis was more sensitive to myocardial changes than longitudinal and radial analysis. The segmental strain/strain rate had an accuracy of 84.3%/70.0% for the diagnosis of an acute myocarditis, stated by EMB and CMR in 42 of 70 patients. In patients with preserved EF, acute myocarditis could be ruled out using only segmental strain analysis with a negative predictive value of 87.5%.ConclusionIn patients with suspected myocarditis, the deformation analysis based on the 17-segment heart model provides valuable information about functional myocardial inhomogeneity. This quantitative approach could be used in addition to the clinical standard CMR protocol and represents a promising tool in the framework of a prospective automatized multiparametric CMR imaging analysis. |
MRF-ZOOM for the unbalanced steady-state free precession (ubSSFP) magnetic resonance fingerprinting Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Ze Wang, Di Cui, Jian Zhang, Ed.X. Wu, Edward S. Hui Abstract
In magnetic resonance fingerprinting (MRF), tissue parameters are determined by finding the best-match to the acquired MR signal from a predefined signal dictionary. This dictionary searching (DS) process is generally performed in an exhaustive manner, which requires a large predefined dictionary and long searching time. A fast MRF DS algorithm, MRF-ZOOM, was recently proposed based on DS objective function optimization. As a proof-of-concept study, MRF-ZOOM was only tested with one of the earliest MRF sequences but not with the recently more popular unbalanced steady state free precession MRF sequence (MRF-ubSSFP, or MRF-FISP). Meanwhile noise effects on MRF and MRF-ZOOM have not been examined. The purpose of this study was to address these open questions and to verify whether MRF-ZOOM can be combined with a dictionary-compression based method to gain further speed. Numerical simulations were performed to evaluate the DS objective function properties, noise effects on MRF, and to compare MRF-ZOOM with other methods in terms of speed and accuracy. In-vivo experiments were performed as well. Evaluation results showed that premises of MRF-ZOOM held for MRF-FISP; noise did not affect MRF-ZOOM more than the conventional MRF method; when SNR ≥ 1, MRF quantification yielded accurate results. Dictionary compression introduced quantification errors more to T2 quantification. MRF-ZOOM was thousands of times faster than the conventional MRF method. Combining MRF-ZOOM with dictionary compression showed no benefit in terms of fitting speed. In conclusion, MRF-ZOOM is valid for MRF- FISP, and can remarkably save MRF dictionary generation and searching time without sacrificing matching accuracy.
|
Tsallis-Entropy Segmentation through MRF and Alzheimer anatomic reference for Brain Magnetic Resonance Parcellation Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Mehran Azimbagirad, Fabrício H. Simozo, Antonio C.S. Senra Filho, Luiz O. Murta Junior Abstract
Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then evaluate an automatic segmentation method based on modified q-entropy (Mqe) through a modified Markov Random Field (MMRF) enhanced by Alzheimer anatomic reference (AAR) to provide a high accuracy brain tissues parcellation approach (Mqe-MMRF). We underwent two strategies to evaluate Mqe-MMRF; a simulation of different levels of noise and non-uniformity effect on MRI data (7 subjects) and a set of twenty MRI data available from MRBrainS13 as patient brain tissue segmentation challenge. We accessed eleven quality metrics compared to reference tissues delineations to evaluate Mqe-MMRF. MRI segmentation scores decreased by only 4.6% on quality metrics after noise and non-uniformity simulations of 40% and 9%, respectively. We found significant mean improvements in the metrics of the five training subjects, for whole-brain 0.86%, White Matter 3.20%, Gray Matter 3.99%, and Cerebrospinal Fluid 4.16% (p-values < 0.02) when Mqe-MMRF compared to the other reference methods. We also processed the Mqe-MMRF on 15 evaluation subjects group from MRBrainS13 online challenge, and the results held a higher rank than the reference tools; FreeSurfer, SPM, and FSL. Since the proposed method improved the precision of brain segmentation, specifically, for GM, and thus one can use it in quantitative and morphological brain studies.
Graphical abstract |
The correlation of fractional anisotropy parameters with Ki-67 index, and the clinical implication in grading of non-enhancing gliomas and neuronal-glial tumors Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Xiang Liu, Wei Tian, Balasubramanya Kolar, Mahlon D. Johnson, Michael T Milano, Haihui Jiang, Song Lin, Dongmei Li, Nimish A. Mohile, Yan M. Li, Kevin A. Walter, Sven Ekholm, Henry Z Wang AbstractPurposeTo investigate the correlation between the FA parameters and Ki-67 labeling index, and their diagnostic performance in grading supratentorial non-enhancing gliomas and neuronal-glial tumors (GNGT).MethodsThis institutional review board-approved, Health Insurance Portability and Accountability (HIPAA) compliant retrospective study enrolled 35 patients, including 19 with low grade GNGT and 16 with high grade GNGT. The mean FA, maximal FA and mean maximal FA values derived from diffusion tensor imaging were measured. The correlation between the FA parameters and the Ki-67 labeling index was assessed by Spearman rank test. The receiver operating characteristic curve analysis and multivariate logistic regression analysis were performed to detect the optimal imaging parameters in grading GNGT.ResultsThe three FA parameters of low grade GNGT were significantly lower than the high grade GNGT (p < 0.001). The mean FA, maximal FA and mean maximal FA had significant positive correlation with Ki-67 labeling index (p = 0.001, p < 0.001, p < 0.001 respectively). The maximal FA showed a higher sensitivity and specificity in grading of non-enhancing GNGT with specificity of 78.9%, sensitivity of 100.0%, respectively.ConclusionsThe FA parameters correlated with Ki-67 labeling index, and were useful surrogates in preoperative grading supratentorial non-enhancing GNGT. |
Generation of human thalamus atlases from 7 T data and application to intrathalamic nuclei segmentation in clinical 3 T T1-weighted images Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Yuan Liu, Pierre-François D'Haese, Allen T. Newton, Benoit M. Dawant Abstract
The thalamus serves as the central relay station for the brain. It processes and relays sensory and motor signals between different subcortical regions and the cerebral cortex and it can be divided into several neuronal clusters referred to as nuclei. Each of these can possibly be subdivided into sub-nuclei. Accurate and reliable identification of thalamic nuclei is important for surgical interventions and neuroanatomical studies. This is however a challenging task because the small size of the nuclei and the lack of contrast over the thalamus region in clinically acquired images does not permit the visualization of their boundaries. A number of methods have been developed for thalamus parcellation but the vast majority of these relies on diffusion imaging or functional imaging. The low resolution of these images only permit localizing the largest nuclei. In this work we propose a method to segment smaller nuclei. We first present a protocol to build histological-like atlases from a series of high-field (7 Tesla) MR images acquired with different pulse sequences that each permits to visualize the boundaries of a subset of the nuclei. We use this protocol to scan 9 subjects and we manually delineate 23 thalamic nuclei following the Morel atlas naming convention for each of these subjects. Manual contours for the nuclei are subsequently utilized to create statistical shape models. With these data, we compare four methods for the segmentation of thalamic nuclei in 3 T images we have also acquired for the 9 subjects included in the study: (1) single atlas, (2) multi atlas, (3) statistical shape, and (4) hierarchical statistical shape in which thalamic nuclei are hierarchically fitted to the images, starting from the largest ones. Results of a leave-one-out validation study conducted on the nine image sets we have acquired show that the multi atlas approach improves upon the single atlas approach for most nuclei. Segmentations obtained with the hierarchical statistical shape model yield the highest accuracy, with dice coefficients ranging from 0.53 to 0.90, mean surface errors from 0.27 mm to 0.64 mm, and maximum surface errors from 1.31 mm to 2.52 mm for all nuclei averaged across test cases. This suggests the feasibility of using such approach for localizing thalamic substructures in clinically acquired MR volumes. It may have a direct impact on surgeries such as Deep Brain Stimulation procedures that require the implantation of stimulating electrodes in specific thalamic nuclei.
|
Quantitative ferumoxytol-enhanced MRI in pregnancy: A feasibility study in the nonhuman primate Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Ante Zhu, Scott B. Reeder, Kevin M. Johnson, Sydney M. Nguyen, Sean B. Fain, Ian M. Bird, Thaddeus G. Golos, Oliver Wieben, Dinesh M. Shah, Diego Hernando AbstractObjectivesTo assess the feasibility of ferumoxytol-enhanced MRI in pregnancy with a nonhuman primate model.Materials and methodsIn this prospective study, eleven pregnant rhesus macaques at day 98 ± 5 of gestation were divided into three groups, untreated control (UC) (n = 3), saline control (SC) (n = 4) and interleukin 1 beta (IL-1β) treated (IT) (n = 4), which were administered with either saline or IL-1β into the amniotic fluid. All animals were imaged at multiple time points before and after ferumoxytol administration (4 mg/kg). Longitudinal R2* and susceptibility of tissues were obtained using region-of-interest analysis and the longitudinal changes were assessed using linear mixed models and Student's t-test.ResultsIn fetuses, a slope of 0.3 s−1/day (P = 0.008), 0.00 ppm/day (P = 0.699) and − 0.2 s−1/day (P = 0.023) was observed in liver R2*, liver susceptibility, and lung R2*, respectively. In placentas, R2* and susceptibility increased immediately after ferumoxytol administration (P < 0.001) and decreased to baseline within two days. The mean change from baseline showed no significant difference between the SC group and the IT group at all scan time points. In maternal livers, R2* increased immediately after ferumoxytol administration, further increased at one-day, and then decreased but remained elevated (P < 0.001). The mean change from baseline showed no significant difference between the SC group and the IT group at all scan time points.ConclusionsThis work demonstrates the feasibility of quantitative ferumoxytol-enhanced MRI to measure dynamics of ferumoxytol delivery and washout in the placenta. Stable MRI measurements indicated no evidence of iron deposition in fetal tissues of nonhuman primates after maternal ferumoxytol exposure. |
Evaluation of B0-correction of relative CBF maps using tagging distance dependent Z-spectrum (TADDZ) Publication date: January 2020 Source: Magnetic Resonance Imaging, Volume 65 Author(s): Frederick C. Damen, Rong-Wen Tain, Riya Thomas, Weigo Li, Leon Tai, Kejia Cai Abstract
Arterial spin labeling (ASL) MRI, based on endogenous contrast from blood water, is used in research and diagnosis of cerebral vascular conditions. However, artifacts due to imperfect imaging conditions such as B0-inhomogeneity (ΔB0) could lead to variations in the quantification of relative cerebral blood flow (CBF). In this study, we evaluate a new approach using tagging distance dependent Z-spectrum (TADDZ) data, similar to the ΔB0 corrections in the chemical exchange saturation transfer (CEST) experiments, to remove the imaging plane B0 inhomogeneity induced CBF artifacts in ASL MRI. Our results indicate that imaging-plane B0-inhomogeneity can lead to variations and errors in the relative CBF maps especially under small tagging distances. Along with an acquired B0 map, TADDZ data helps to eliminate B0-inhomogeneity induced artifacts in the resulting relative CBF maps. We demonstrated the effective use of TADDZ data to reduce variation while subjected to systematic changes in ΔB0. In addition, TADDZ corrected ASL MRI, with improved consistency, was shown to outperform conventional ASL MRI by differentiating the subtle CBF difference in Alzheimer's disease (AD) mice brains with different APOE genotypes.
|
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Τρίτη 19 Νοεμβρίου 2019
Αναρτήθηκε από
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
στις
11:04 μ.μ.
Ετικέτες
00302841026182,
00306932607174,
alsfakia@gmail.com,
Anapafseos 5 Agios Nikolaos 72100 Crete Greece,
Medicine by Alexandros G. Sfakianakis,
Telephone consultation 11855 int 1193
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου